| DC INVERTER | JP/GW-26BPCH(G) | JP/GW-35BPCH(G) | JP/GW-50BPCH(G) | JP/GW-70BPCH(G) | ||
| Rated Power supply | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | ||
| Workable Power supply | 1Ph / 150-260V/50Hz | 1Ph / 150-260V/50Hz | 1Ph / 160-260V/50Hz | 1Ph / 160-260V/50Hz | ||
| Cooling | Capacity (btu/h) | 9000 | 12000 | 18000 | 24000 | |
| Capacity (W) | 2500(150~3000)W | 3500(150~3600)W | 5300(1250-5910) | 7300(1830~7800) | ||
| Input (W) | 900(100~1200)W | 1180(75~1560)W | 1780(330-2340) | 2350(410~2830) | ||
| Rated current (A) | 4.0 (0.8~5.3)A | 5.7(0.5~6.9)A | 7.9(1.7~12.0) | 10.5(2.3~12.3) | ||
| EER | 2.90 | 2.90 | 2.90 | 2.90 | ||
| Heating | Capacity (btu/h) | 9000 | 12000 | 18000 | 24000 | |
| Capacity (W) | 2800(150~3300)W | 3700(150~3900)W | 5600(1250-6070) | 7600(1850~7900) | ||
| Input (W) | 960(75~1260)W | 1260(75~1580)W | 1670(340-2520) | 2240(420~3000) | ||
| Rated current (A) | 4.3(0.5~5.6) | 5.6(0.5~7.0)A | 7.5(1.7~13.0) | 10.0(2.3~13.5) | ||
| COP | 3.30 | 3.3 | 3.30 | 3.30 | ||
| Max. input consumption (W) | 1600 | 1720 | 2520 | 3100 | ||
| Max. current (A) | 8.50 | 9.00 | 13.00 | 14.80 | ||
| Compressor | Type | Rotary | Rotary | Rotary | Rotary | |
| Brand | GMCC,GREE | GMCC | GMCC | GMCC | ||
| Indoor unit | Indoor Coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | ||
| Indoor air flow (Turbo/Hi/Mi/Lo) (M3/h) | 500/450/370/320 | 550/500/450/370 | 850/750/650/580 | 1050/950/800/680 | ||
| Rated input Power(cooling/heating) (W) | 30 | 30 | 35 | 45 | ||
| Rated current (cooling/heating) (A) | 0.2 | 0.2 | 0.35 | 0.4 | ||
| Moisture Removal (KG/h) | 0.8 | 0.8 | 2 | 2.6 | ||
| Noise level(Turbo/Hi/Mi/Lo) (dB(A)) | 39/34/32/30 | 42/39/36/33 | 45/42/39/37 | 49/47/45/42 | ||
| Unit dimension (W*H*D) | 610×295×495 | 780×275×190 | 810×295×205 | 955x335x230 | ||
| Packing (W*H*D) | 704×324×530 | 847×322×241 | 875×340×255 | 1020×400×300 | ||
| Net weight (KGs) | 6 | 7 | 8.5 | 12 | ||
| Gross weight (KGs) | 8 | 9 | 10.5 | 14 | ||
| Outdoor unit | Outdoor coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ7mm, Inner Grooved | ||
| Noise level (dB) | 50 | 52 | 55 | 59 | ||
| Unit dimension (W*D*H) (mm) | 670(610)×295×495 | 780(710)×295×495 | 800(730)×305×550 | 850(780)×350×600 | ||
| Packing (W*D*H) (mm) | 704×324×530 | 818×328×530 | 835×340×580 | 896×387×625 | ||
| Net weight (KGs) | 20 | 21 | 24 | 26 | ||
| Gross weight (KGs) | 23 | 24 | 27 | 30 | ||
| Refrigerant type | R32 | R32 | R32 | R32 | ||
| Refrigerant pipe | Liquid side (mm) | Φ6 | Φ6 | Φ6 | Φ6 | |
| Gas side (mm) | Φ9 | Φ9 | Φ12 | Φ15.88 | ||
| Max. refrigerant pipe length (m) | 10 | 10 | 10 | 15 | ||
| Max. difference in level (m) | 5 | 5 | 5 | 10 | ||
| Operation temperature range | -7℃-43℃ | -7℃-43℃ | -7℃-43℃ | -7℃-43℃ | ||
| Ambient temperature range | -7℃-48℃ | -7℃-48℃ | -7℃-48℃ | -7℃-48℃ | ||
| Application area (MM2) | 10~17 | 13~27 | 20~40 | 30~55 | ||
| Sets per 40ft HQ/20ft | 382/167 | 334/143 | 286/124 | 196 / - | ||
It’s not just a trend anymore; it’s a necessity. As temperatures soar, the demand for effective cooling solutions rises. Enter heat pump Air Conditioners. Why are they gaining traction in factories across China? Let’s delve into this phenomenon.
The Mechanics Behind Heat Pumps
A heat pump air conditioner operates on a simple yet ingenious principle. It transfers heat from one place to another, allowing it to provide both heating and cooling, depending on the season. In contrast to traditional Air Conditioners that merely cool the air, these devices can significantly enhance energy efficiency. Did you know that a good heat pump can achieve a coefficient of performance (COP) of 4 or more? This means it can produce four units of heating or cooling for every unit of electricity consumed.
Key Features and Technologies
- Inverter Technology: This allows for variable speed operation, adjusting compressor speed as needed. Result? Consistent temperature control and energy savings.
- Eco-Friendly Refrigerants: Brands like Pazoeoeic Air Conditioner are now integrating refrigerants with lower global warming potential, making these systems more environmentally friendly.
- Advanced Filtration Systems: They ensure superior air quality by trapping dust and allergens, a crucial factor in industrial settings where air purity is paramount.
Case Study: A Chinese Factory Transformation
Consider a textile manufacturing plant in Zhejiang province. Before switching to heat pump air conditioning, they relied on outdated chillers that guzzled power. Their monthly energy bill? A staggering $10,000! After installing a modern heat pump system with inverter technology, their costs dropped to $6,000. Not only did they save money, but productivity also soared as workers enjoyed a more comfortable environment.
Market Dynamics and Wholesale Opportunities
The wholesale market for heat pump Air Conditioners in China is booming. Several manufacturers are ramping up production to meet growing demands. The entry barriers are lower than ever, making it attractive for new players. For wholesalers, partnering with established brands like Pazoeoeic offers an edge in quality assurance and brand recognition. Statistics show that factories prefer working with suppliers who have proven reliability and robust after-sales service.
Challenges Ahead
However, it's not all smooth sailing. Some concerns linger regarding installation complexity and upfront costs. Wholesalers must educate clients about long-term benefits versus initial investment. What good is saving on utility bills if the installation process turns into a nightmare?
- Installation Expertise: Many technicians lack training in advanced heat pump systems.
- Consumer Education: Misconceptions about heat pump efficiency still persist among end-users.
Future Outlook
The future appears bright for heat pump air conditioners. With increasing government incentives for renewable energy solutions, along with rising environmental awareness, demand will likely continue to grow. By 2025, experts project that the market will expand by over 30%. As factories search for sustainable solutions, heat pumps will become indispensable.
In conclusion, the evolution of heat pump air conditioners represents more than just an advancement in technology; it signifies a shift toward a more energy-efficient and sustainable industrial landscape. Are you ready to embrace this change?